A mixture design procedure was developed for large stone mixtures with maximum aggregate sizes of 25 mm to 63 mm. The design procedure makes use of existing contractor stockpile gradations with the intent of maximizing the load carrying role of the stockpile containing the largest aggregate. Evaluative laboratory test procedures were developed and tested. A full scale test pavement demonstrated the effectiveness of the procedure.